Load-bearing sheet T200 – 75L-840

Load-bearing sheet  T200 – 75L-840

Load-bearing sheets are suitable for roof decking, external roof sheeting and intermediate flooring, and they can also be used as formwork for concrete slabs. For the most economical design, use Ruukki’s Poimu roof-dimensioning software.

 


Feedback


Person to contact: *
Tel: *
E-mail: *
Company / Organisation:
City:
Quantity:
Your message: *
Security code:*


Fields marked with * are required!!!



  • Properties
  • Materials
  • Design tools
  • Installation
  • Safety
  • Services & options
  • Order & delivery

Properties

The small arrow indicates the side where coating is applied on the sheet.

Note! Load-bearing sheets are delivered with the narrow flange facing up and wide flange facing down, check if you need to turn the sheet for installation.

 

Product properties

Ruukki T200-75L-840
  T = Trapezoidal sheet
  200 = Height class
  75 = Flange width
 

L = Load bearing profile

  840 =Modular width
Height: 200 mm
Modular width: 840 mm
Thicknesses available: 0.75–1.25 mm
Thicknesses in stock: 0.75,  0.88, 1.0, 1.25 mm
Minimum length: 500 mm
Maximum length: 13500 mm
Quality control: Factory production control according to EN 14782 and EN 1090.
Material:

Hot dip galvanised S320GD+Z steel sheet
Galvanised: according to EN 10346
Coil-coated: according to EN 10169-1

Tolerances: Product: EN 508-1
Raw material: EN 10143

Materials

Thickness

 CoatingZincCorrosion classes Steel gradeWeightColours
mm     Interior Exterior   kg/m2  
0.75 Polyester 15 Z100 C1-C2   S320 10.71 RAL9001,9002,9006,2010
0.88 Polyester 15 Z100 C1-C2   S320 12.57 RAL9001,9002,9006,2010
1 Polyester 15 Z100 C1-C2   S320 14.29 RAL9001,9002,9006,2010
1.25 Polyester 15 Z100 C1-C2   S320 17.86 RAL9001,9002,9006,2010

Protection against corrosion

 

 Environment Coating
Inside buildings in environments with corrosivity category C1, C2 according to EN ISO 12944-2 standard and A1, A2 according to EN 10169 standard Steel sheets with zinc coating of 100 g/m2 and with polyester coating SP 15, thickness 15 μm
Interior applications in environments with corrosivity category C1, C2, C3 according to EN ISO 12944-2 standard and A1, A2, A3 according to EN 10169 standard Steel sheets with zinc coating of 275 g/m2 and with polyester coating SP 25, thickness 25 μm

Corrosivity categories according to EN ISO 12944-2 standard, examples

Corrosivity category C1:

  • Interior – heated building with clean atmospheres, e.g. offices, shops, schools, hotels

Corrosivity category C2:

  • Interior – unheated buildings where condensation may occur, e.g. depots, sports halls

Corrosivity category C3:

  • Interior – production rooms with high humidity and some air pollution, e.g. food-processing plants, laundries, breweries, dairies
  • Exterior- urban and industrial atmospheres, moderate sulfur dioxide pollution. Coastal areas with low salinity.

Corrosivity category C4:

  • Exterior -industrial areas and coastal areas with moderate salinity.

Corrosivity categories according to EN 10169 standard (condensation), examples

Corrosivity category A1:

  • Interior – office buildings, schools, residential (except kitchens and bathrooms), dry storage buildings

Corrosivity category A2:

  • Interior – sports halls, cinemas, theatres, cold stores, supermarkets

Corrosivity category A3:

  • Interior – kitchens and bathrooms, food processing (e.g. bakeries), industrial buildings with dry process

Design tools

Dimensioning software Poimu

 

Ruukki offers excellent dimensioning software Poimu, which enables to optimize product choice according to the Eurocode.

 

Just by defining some basic input data you can select a load-bearing sheet for your needs from Ruukki´s selection. This quick optimization tool covers 1-, 2-span and continuous structures and gives the exact solution of sheet that should be used, as well as its length.

 

Download Poimu from Software Toolbox

Detail drawings DWG

Installation

Note! When delivered, the narrow flange of the load-bearing roofing sheet faces upwards in the package, so check if the sheet needs to be turned to be installed correctly.

  • For insulated roofing structures, the load-bearing sheet needs to be turned, as it is installed with the narrow flange against the support. An exception is the anti-condensation coated sheet, which is delivered with the wide flange facing upwards, when semi-warm roof is in question.
  • For uninsulated roofs, the sheet is installed as delivered, with the wide flange against the support.

  1. Installation instructions PDF
  2. Storage instructions PDF

Safety

Ensuring the health and safety of workers is our priority. We have developed the perfect tools for Ruukki load-bearing sheet site actions. The lifting tool is for lifting load-bearing sheets safely, the safety anchor is for working safely on the roof. The tools are CE-marked and can be used only with Ruukki´s load-bearing sheets.

We recommend using our health and safety equipment when handling and installing load-bearing sheets.

National restrictions might be in place. Please check local usage possibilities from us

Services & options

Web perforation

Standard perforation grade (within perforation area) is 15%. Diameter of perforation holes is 3 mm which are spaced on the basis of equilateral triangle, side equals 7.4 mm.

Due to web perforation of load-bearing trapezoidal sheets, decrease of strength parameters takes place.

In order to determine load capacity of perforated profiles, you are recommended to use Poimu software, which enables dimensioning and optimization of trapezoidal sheets within structure.

 

Acoustics

When you need reduction for reverberation time, please ask for further information from our sales. Our load-bearing profile sheets are tested with different kinds of roof build-ups to meet your needs. We are not limited to only sound absorption, our experts are also ready to consult you regarding the roof sound insulation.  

 

Anti-condensation

When building cold storage or car shelters, please remember that condensation might be harmful. To avoid this, we can provide our load-bearing sheets with anti-condensation layers.

Order & delivery

Изтеглете декларация за технически показатели от тук.

 

За поръчка се обърнете към :

Офис RUUKKI в България: Р.К.И. (Руукки Конструкции и Инженеринг) България ООД:

1606 София, ул. Евлия челеби No22,  

Тел. 02/9693046

e-mail: valentin.valov@ruukki.com

Properties

The small arrow indicates the side where coating is applied on the sheet.

Note! Load-bearing sheets are delivered with the narrow flange facing up and wide flange facing down, check if you need to turn the sheet for installation.

 

Product properties

Ruukki T200-75L-840
  T = Trapezoidal sheet
  200 = Height class
  75 = Flange width
 

L = Load bearing profile

  840 =Modular width
Height: 200 mm
Modular width: 840 mm
Thicknesses available: 0.75–1.25 mm
Thicknesses in stock: 0.75,  0.88, 1.0, 1.25 mm
Minimum length: 500 mm
Maximum length: 13500 mm
Quality control: Factory production control according to EN 14782 and EN 1090.
Material:

Hot dip galvanised S320GD+Z steel sheet
Galvanised: according to EN 10346
Coil-coated: according to EN 10169-1

Tolerances: Product: EN 508-1
Raw material: EN 10143

Materials

Thickness

 CoatingZincCorrosion classes Steel gradeWeightColours
mm     Interior Exterior   kg/m2  
0.75 Polyester 15 Z100 C1-C2   S320 10.71 RAL9001,9002,9006,2010
0.88 Polyester 15 Z100 C1-C2   S320 12.57 RAL9001,9002,9006,2010
1 Polyester 15 Z100 C1-C2   S320 14.29 RAL9001,9002,9006,2010
1.25 Polyester 15 Z100 C1-C2   S320 17.86 RAL9001,9002,9006,2010

Protection against corrosion

 

 Environment Coating
Inside buildings in environments with corrosivity category C1, C2 according to EN ISO 12944-2 standard and A1, A2 according to EN 10169 standard Steel sheets with zinc coating of 100 g/m2 and with polyester coating SP 15, thickness 15 μm
Interior applications in environments with corrosivity category C1, C2, C3 according to EN ISO 12944-2 standard and A1, A2, A3 according to EN 10169 standard Steel sheets with zinc coating of 275 g/m2 and with polyester coating SP 25, thickness 25 μm

Corrosivity categories according to EN ISO 12944-2 standard, examples

Corrosivity category C1:

  • Interior – heated building with clean atmospheres, e.g. offices, shops, schools, hotels

Corrosivity category C2:

  • Interior – unheated buildings where condensation may occur, e.g. depots, sports halls

Corrosivity category C3:

  • Interior – production rooms with high humidity and some air pollution, e.g. food-processing plants, laundries, breweries, dairies
  • Exterior- urban and industrial atmospheres, moderate sulfur dioxide pollution. Coastal areas with low salinity.

Corrosivity category C4:

  • Exterior -industrial areas and coastal areas with moderate salinity.

Corrosivity categories according to EN 10169 standard (condensation), examples

Corrosivity category A1:

  • Interior – office buildings, schools, residential (except kitchens and bathrooms), dry storage buildings

Corrosivity category A2:

  • Interior – sports halls, cinemas, theatres, cold stores, supermarkets

Corrosivity category A3:

  • Interior – kitchens and bathrooms, food processing (e.g. bakeries), industrial buildings with dry process

Design tools

Dimensioning software Poimu

 

Ruukki offers excellent dimensioning software Poimu, which enables to optimize product choice according to the Eurocode.

 

Just by defining some basic input data you can select a load-bearing sheet for your needs from Ruukki´s selection. This quick optimization tool covers 1-, 2-span and continuous structures and gives the exact solution of sheet that should be used, as well as its length.

 

Download Poimu from Software Toolbox

Detail drawings DWG

Installation

Note! When delivered, the narrow flange of the load-bearing roofing sheet faces upwards in the package, so check if the sheet needs to be turned to be installed correctly.

  • For insulated roofing structures, the load-bearing sheet needs to be turned, as it is installed with the narrow flange against the support. An exception is the anti-condensation coated sheet, which is delivered with the wide flange facing upwards, when semi-warm roof is in question.
  • For uninsulated roofs, the sheet is installed as delivered, with the wide flange against the support.

  1. Installation instructions PDF
  2. Storage instructions PDF

Safety

Ensuring the health and safety of workers is our priority. We have developed the perfect tools for Ruukki load-bearing sheet site actions. The lifting tool is for lifting load-bearing sheets safely, the safety anchor is for working safely on the roof. The tools are CE-marked and can be used only with Ruukki´s load-bearing sheets.

We recommend using our health and safety equipment when handling and installing load-bearing sheets.

National restrictions might be in place. Please check local usage possibilities from us

Services & options

Web perforation

Standard perforation grade (within perforation area) is 15%. Diameter of perforation holes is 3 mm which are spaced on the basis of equilateral triangle, side equals 7.4 mm.

Due to web perforation of load-bearing trapezoidal sheets, decrease of strength parameters takes place.

In order to determine load capacity of perforated profiles, you are recommended to use Poimu software, which enables dimensioning and optimization of trapezoidal sheets within structure.

 

Acoustics

When you need reduction for reverberation time, please ask for further information from our sales. Our load-bearing profile sheets are tested with different kinds of roof build-ups to meet your needs. We are not limited to only sound absorption, our experts are also ready to consult you regarding the roof sound insulation.  

 

Anti-condensation

When building cold storage or car shelters, please remember that condensation might be harmful. To avoid this, we can provide our load-bearing sheets with anti-condensation layers.

Order & delivery

Изтеглете декларация за технически показатели от тук.

 

За поръчка се обърнете към :

Офис RUUKKI в България: Р.К.И. (Руукки Конструкции и Инженеринг) България ООД:

1606 София, ул. Евлия челеби No22,  

Тел. 02/9693046

e-mail: valentin.valov@ruukki.com